FIG. 1 is a left front bottom perspective view of a first embodiment of a breaker bar showing my new design;
HandBrake is an open-source, GPL-licensed, multiplatform, multithreaded video transcoder. Download Heart Breaker - Hand Lettered SVG today! We have a huge range of SVGs products available. Commercial License Included.
Hand Breaker Free Download
FIG. 2 is a left back top perspective view thereof;
FIG. 3 is a front elevational view thereof;
FIG. 4 is a back elevational view thereof;
FIG. 5 is a right-side elevational view thereof (which is the same as the left-side elevational view thereof);
FIG. 6 is a bottom plan view thereof;
FIG. 7 is a top plan view thereof; and
FIG. 8 is a cross-sectional view thereof taken along lines VIII-VIII of FIG. 6.
FIG. 9 is a left front bottom perspective view of a second embodiment of the breaker bar;
FIG. 10 is a left back top perspective view thereof;
FIG. 11 is a front elevational view thereof;
FIG. 12 is a back elevational view thereof;
FIG. 13 is a right-side elevational view thereof;
FIG. 14 is a bottom plan view thereof;
FIG. 15 is a top plan view thereof; and,
FIG. 16 is a cross-sectional view thereof taken along lines XVI-XVI of FIG. 12 o clock movie download. 14.
The broken lines are included for purposes of illustrating environment and form no part of the claimed design. The Article is shown with a symbolic break in its length. The appearance of any portion of the article between the break lines forms no part of the claimed design.
1.Ionization in circuit breakers is facilitated by
a) Increase of field strength
b) Increase of mean free path
c) High temperature
d) All of these
Ans: (d)
a) High resistance interruption
b) Low resistance interruption
c) Both (a) and (b)
d) None of these
Ans: (c)
Hand Breaker Download
a) Trip Coil
b) Contacts
c) Handle
d) Medium
Ans: (b)
a) Manually
b) Automatically
c) That it should give warning
d) None of these
Ans: (b)
a) Separation of circuit breaker and extinction of arc
b) Separation of circuit breaker and rise of recovery voltage
c) Normal current interruption and arc extinction
d) None of these
Ans: (a)
a) Restriking voltage
b) Recovery voltage
c) Rate of rise restriking voltage
d) Active recovery voltage
Ans: (c)
The broken lines are included for purposes of illustrating environment and form no part of the claimed design. The Article is shown with a symbolic break in its length. The appearance of any portion of the article between the break lines forms no part of the claimed design.
1.Ionization in circuit breakers is facilitated by
a) Increase of field strength
b) Increase of mean free path
c) High temperature
d) All of these
Ans: (d)
a) High resistance interruption
b) Low resistance interruption
c) Both (a) and (b)
d) None of these
Ans: (c)
Hand Breaker Download
a) Trip Coil
b) Contacts
c) Handle
d) Medium
Ans: (b)
a) Manually
b) Automatically
c) That it should give warning
d) None of these
Ans: (b)
a) Separation of circuit breaker and extinction of arc
b) Separation of circuit breaker and rise of recovery voltage
c) Normal current interruption and arc extinction
d) None of these
Ans: (a)
a) Restriking voltage
b) Recovery voltage
c) Rate of rise restriking voltage
d) Active recovery voltage
Ans: (c)
a) Closing time
b) Opening time
c) Both (a) and (b)
d) None of these
Ans: (d)
a) Lengthening of the gap
b) Cooling
c) Blast effect
d) All of these
Ans: (d)
a) Active recovery voltage
b) Natural frequency of oscillations
c) Both (a) and (b)
d) Rating of circuit breaker
Ans: (c)
a) Zero & infinite impedance before & after interruption respectively
b) Infinity & zero impedance before & after interruption respectively
c) Equal impedance before & after interruption
d) None of these
Ans: (a)
Related topics :
Recent Post
Multiple Choice Question (MCQ) of Electronics page-17: |
Multiple Choice Question (MCQ) of Electronics page-16: |
Multiple Choice Question (MCQ) of Electronics page-15: |
Multiple Choice Question (MCQ) of Electronics page-14: |
Multiple Choice Question (MCQ) of Electronics page-13: |